2

90914

INSTALLATION INSTRUCTIONS

UNPACKING INSTRUCTIONS

1. With the unit upright, carefully remove the shipping crate. Inspect for shipping damage and report any such

damage to the shipper immediately.

2. Open the hinged service door and remove shipping tape from the ice drop cover, storage hopper cover and

agitator in the storage hopper.

3. Remove shipping tape from air inlet filter and sink grill.

INSTALLATION

NOTE:

An Everpure Model 9320-42 Systems IV, Model B1000 (or equal) ice maker quality water

treatment unit MUST BE INSTALLED in the water supply line to the ice maker. Failure to do so

may result in poor quality ice, low production output, and may cause premature failure of the

ice maker evaporator and void the extended evaporator warranty.

This ice maker is provided with a stainless steel evaporator designed to last the life of the product. But, some of

the chemicals in treated and untreated water, specifically chlorine and sulphur (sulphide), have the ability to at-

tach stainless steel and cause premature failure. An initial investment in proper water treatment will pay for itself

in increased production, quality and long life of the product.

1. Location

Locate the ice maker/dispenser indoors in a well-ventilated area. Avoid exposure to direct sunlight and/or

heat caused by radiation.

Ambient room temperature must be in the range of 60° to 90° F. Do not install unit in an enclosed area

where heat build up could be a problem. For proper air flow for the refrigeration system, allow a 6?clear-

ance at the back of the unit and a 12?clearance at the right side panel.

Consult Figure 1 for utility connection location.

Consult Figure 2 for dimensions for mounting unit to the counter with the hardware provide. Note that the

unit must be level for proper operation.

The unit must be sealed to the counter. The mounting template drawing (Figure 2) indicated the openings

which must be cut in the counter. Locate the desired position for the unit, then mark the outline dimensions

and cut-out locations using the template drawing. Cut openings in counter.

Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow 732 or equal) approximate-

ly 1/4?inside of the unit outline dimensions and around all openings. Then position the unit on the counter

within the outline dimensions. All excess sealant must be wiped away.

2. Plumbing

Connect the ice maker to a cold, potable water source suitable for drinking. Do not install unit on a water

softener line. It is recommended that a hand shut-off valve, strainer, and backflow preventer be used on the

incoming supply line. For Models: SID851/250S and SID851/250S-B, a 3/8?outside diameter compression

tube fitting is provided at the back of the unit for the water supply hook up (See Figure 1). For model

SID851/250S-BC, a 3/8?beverage tubing with a 3/8 x 1/4 barb splicer fitting is provided for connection

through the bottom opening in the unit to the water supply (See Figure 2).