Ethernet controller messages – IBM 5000 User Manual

Page 149

Advertising
background image

Ethernet Controller Messages

pnt0-12

Device failed checksum test!

Explanation: The driver cannot find an Ethernet controller.

Action: Verify that the PCI Ethernet device type is set to the default (enabled) position in the
Configuration/Setup utility programs (see “PCI Bus Control” on page 29). If the Ethernet adapter is
enabled, go to “Diagnostic Test Programs” on page 111 to run the diagnostic utility.

pnt0-13

add_intr_handler failed! Interrupts already enabled.

Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.

Action: Modify your hardware settings.

Run the NETCONFIG program to match the hardware settings.

pnt0-14

Cannot locate hardware.

Explanation: The SunSoft Solaris driver cannot find any Ethernet controller.

Action: Verify that the PCI Ethernet device type is set to the default (enabled) position in the
Configuration/Setup utility programs (see “PCI Bus Control” on page 29). If the Ethernet adapter is
enabled, go to “Diagnostic Test Programs” on page 111 to run the diagnostic utility.

pnt0-15

No more devices to open.

Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers.

Action: Verify that additional Ethernet adapters are present or replace the Ethernet adapter that fails to
respond. If the problem persists, go to “Diagnostic Test Programs” on page 111 to run the diagnostic
utility.

pnt0-17

Device fault...Reset initiated!

Explanation: The SunSoft Solaris driver has been reset due to a device fault.

Action: Verify that additional Ethernet adapters are present or replace the Ethernet adapter that fails to
respond. If the problem persists, go to “Diagnostic Test Programs” on page 111 to run the diagnostic
utility.

pnt0-19

IRQ found for PCnet hardware does not match space.c (or pnt.conf)!

Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.

Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings.

pnt0-20

add_intr_handler failed! Unknown interrupt type.

Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.

Action: Modify your hardware settings.

Run the NETCONFIG program to search for another Ethernet controller.

pnt0-21

add_intr_handler failed! Out of range interrupt number.

Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.

Action: Modify your hardware settings.

Run the NETCONFIG program to search for another Ethernet controller.

pnt0-22

add_intr_handler failed! Out of range IPL.

Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with
other devices in the server.

Action: Modify your hardware settings.

Run the NETCONFIG program to search for another Ethernet controller.

Chapter 6. Solving Problems