Figure 14. mii clocks ac timing, 2 mii timing parameters, Figure 15. mii transmit timing parameters – Intel 82555 User Manual

Page 50: Mii timing parameters

Advertising
background image

82555 — Networking Silicon

46

Datasheet

11.4.2

MII Timing Parameters

Figure 14. MII Clocks AC Timing

T1,T2,T3

1.5V

T4,T5,T6

T4,T5,T6

Symbol

Parameter

Conditions

Min

Typ

Max

Units

T7

T

TXDV

TXD[3:0], TXEN, TXERR setup
from the rising edge of TXC

15

25

ns

T8

T

TXH

TXD[3:0], TXEN, TXERR hold
time after the rising edge of TXC

0

ns

T9

T

RXSU

RXD[3:0], RXDV, RXERR valid
before the rising edge of RXC

10

ns

T10

T

RXH

RXD[3:0], RXDV, RXERR hold
time after the rising edge of RXC

10

ns

T11

T

MSU

MDIO setup time to the rising
edge of MDC

MDIO input

10

ns

T12

T

MH

MDIO hold time from the rising
edge of MDC

MDIO input

10

ns

T13

T

MV

MDIO valid from the rising edge
of MDC

MDIO output

300

ns

Figure 15. MII Transmit Timing Parameters

T7

T8

TXCLK

TXD[3:0],

TXER,TXEN

Data Invalid

Data Invalid

Data Valid