Page 50: Mii timing parameters
Advertising

82555 — Networking Silicon
46
Datasheet
11.4.2
MII Timing Parameters
Figure 14. MII Clocks AC Timing
T1,T2,T3
1.5V
T4,T5,T6
T4,T5,T6
Symbol
Parameter
Conditions
Min
Typ
Max
Units
T7
T
TXDV
TXD[3:0], TXEN, TXERR setup
from the rising edge of TXC
15
25
ns
T8
T
TXH
TXD[3:0], TXEN, TXERR hold
time after the rising edge of TXC
0
ns
T9
T
RXSU
RXD[3:0], RXDV, RXERR valid
before the rising edge of RXC
10
ns
T10
T
RXH
RXD[3:0], RXDV, RXERR hold
time after the rising edge of RXC
10
ns
T11
T
MSU
MDIO setup time to the rising
edge of MDC
MDIO input
10
ns
T12
T
MH
MDIO hold time from the rising
edge of MDC
MDIO input
10
ns
T13
T
MV
MDIO valid from the rising edge
of MDC
MDIO output
300
ns