Cemt set gtftrace, Cemt set inttrace – IBM CICS Transaction Server for OS/390 SC33-1686-02 User Manual

Page 202

Advertising
background image

CEMT SET GTFTRACE CEMT SET INTTRACE


CEMT SET GTFTRACE

Function:

Change the status of GTF tracing

Description:

SET GTFTRACE allows you to switch CICS

tracing to the MVS Generalized Tracing Facility (GTF) on
and off.

This command is intended for use at terminals that do not
support the CETR full-screen tracing transaction.

For guidance on using GTF tracing, see the

CICS Problem

Determination Guide.

Syntax:

Press the Clear key to clear the screen. There are

two ways of commencing this transaction:

Type

CEMT SET GTFTRACE

(the minimum abbreviation is

CEMT S G

). You get a display that lists the current status,

similar to that obtained by CEMT INQUIRE GTFTRACE.
You can then tab to the highlighted field and overtype it
with the required value.

Type

CEMT SET GTFTRACE

(

CEMT S G

) followed by the

attribute setting that you wish to change. For example,

cemt s g sta

will cause CICS GTF tracing to be started.

Typing ? at the beginning of either the first or second line
gives a syntax prompt. Resetting the values takes effect
immediately.

─CEMT Set Gtftrace

─┬

───────

─STArt─

─STOp──

Options

STArt

CICS tracing to the MVS Generalized Tracing Facility
(GTF) is started.

STOp

CICS tracing to the MVS Generalized Tracing Facility
(GTF) is stopped.

CEMT SET INTTRACE

Function:

Switch CICS internal tracing on or off.

Description:

SET INTTRACE allows you to switch CICS

internal tracing on and off.

This command is intended for use at terminals that do not
support the full-screen tracing transaction CETR.

Syntax:

Press the Clear key to clear the screen. There are

two ways of commencing this transaction:

Type

CEMT SET INTTRACE

(the minimum abbreviation is

CEMT S IN

). You get a display that lists the current

status, similar to that obtained by CEMT INQUIRE
INTTRACE. You can then tab to the highlighted field and
overtype it with the required value.

Type

CEMT SET INTTRACE

(

CEMT S IN

) followed by the

attribute setting that you wish to change. For example,

cemt s in sta

will cause CICS internal tracing to be

started.

Typing ? at the beginning of either the first or second line
gives a syntax prompt. Resetting the values takes effect
immediately.

─CEMT Set INttrace

─┬

───────

─STArt─

─STOp──

Options

STArt

CICS internal tracing is started.

STOp

CICS internal tracing is stopped.

184

CICS Supplied Transactions

Advertising