CEMT INQUIRE DUMPDS

CEMT INQUIRE DUMPDS

Function:

Retrieve information about the CICS dump data

sets.

Description:

INQUIRE DUMPDS tells you which dump

data set (A or B) is currently open.

Instead of using the SET command, you can overtype your
changes on the INQUIRE screen after tabbing to the
appropriate field. See “Overtyping a display” on page 47.

For information on using dumps, see the

CICS Problem

Determination Guide.

Input:

Press the Clear key and type

CEMT INQUIRE DUMPDS

(the minimum abbreviation is

CEMT I DU

).

You will get a display screen, a sample of which is shown
below. If you want to change any of the values shown, you
can then tab to the highlighted or blank fields and overtype
them as required.

Sample screen

IN DUMPDS
STATUS: RESULTS - OVERTYPE TO MODIFY

Dum Cur(A) Ope

Figure 67. CEMT INQUIRE DUMPDS screen

Note: There are blank fields on the screen where a value

does not apply or is ‘negative’; that is, the value
begins with ‘No’. To modify these fields, locate them
by tabbing (they appear in the same sequence as in
the expanded format), and overtype with input valid
for that field. You may find it more convenient to use
the expanded format when setting one of these
values, (negating is easier because you are
overtyping a displayed field with its negative causing
the result to become non-displayed).

If you place the cursor against the result and press ENTER,
CICS displays an expanded format as shown in Figure 68.

IN DUMPD
RESULT - OVERTYPE TO MODIFY

Dumpds

Currentdds(A)
Openstatus( Open )
Switchstatus( Noautoswitch )

Figure 68. The expanded display

─CEMT Inquire DUmpds ─

Displayed fields

DUmpds

indicates that this panel relates to a dump data set
inquiry.

Currentdds(

value)

displays a 1-character indicator as to which of the two
dump data sets is active. This can be A or B.

Openstatus

displays the status of the active CICS dump data set.
The values are:

Open

The active CICS dump data set is open.

Closed

The active CICS dump data set is closed.

Switch

The currently active dump data set is to become
inactive, and the currently inactive data set is to
become active.

Note: You can reset this value by overtyping it with a

different value.

Switchstatus

displays whether there is to be an automatic switch to
the inactive dump data set when the active dump data
set is full. The values are:

Autoswitch

The switch occurs only when the active dump
data set is full, but not subsequently.

Noautoswitch

When the active dump data set is full, there is not
to be an automatic switch to the inactive dump
data set.

Note: Because this is a ‘negative’ attribute, the

field appears blank. You can, however, tab
to this field and overtype it with a different
value.

Note: You can reset this value by overtyping it with a

different value.

Chapter 11. Master terminal CEMT

79

Advertising