CEMT SET SYDUMPCODE

NODae

A system dump will not be suppressed by the DAE
component. (However, be aware of the SUPPRESS and
SUPPRESSALL options in the ADYSETxx parmlib
member. These are controlled by the VRADAE and
VRANODAE keys in the SDWA. They may lead to dump
suppression even though NODAE is set here. For
information about DAE, SUPPRESS, and
SUPPRESSALL, see the

OS/390 MVS Diagnosis: Tools

and Service Aids manula.

NOSHutdown

CICS is not to be shut down after the occurrence of an
error corresponding to this dump code.

NOSYsdump

A system dump is not to be taken for this system dump
code.

RELated

A system dump request is to be sent to MVS images in
the sysplex which are running XCF/MRO connected

CICS regions related to the CICS region on which the
dump is initiated.

Note: A related CICS region is one in which the unit of

work identifiers, in the form of APPC tokens, of
one or more tasks match those in the CICS
region that issued the dump request.

REMove

This system dump code is removed from the system
dump code table.

RESet

The current number of calls for this dump code is reset
to zero.

SHutdown

CICS is to be shut down.

SYsdump

A system dump is to be taken for this system dump
code.