ICP DAS USA IM-100 User Manual

Page 77

Advertising
background image

IMC_OutputPort_Configure

Syntax:

Visual C++ 6.0 / Boland C++ Builder 6.0:

short IMC_OutputPort_Configure ( HANDLE Camera_Handle, int Output_Port, int

Source_Signal);

Visual Basic 6.0

IMC_OutputPort_Configure (ByVal Camera_Handle As Long, ByVal Output_Port As

Long, ByVal Source_Signal As Long) As Integer

C#.NET 2003

Mavis.IMC_OutputPort_Configure( IntPtr Camera_Handle, int Output_Port, int

Source_Signal );

Description:

This function configures the hardware sources for specific Output Port. The camera

needs be initialized with IMC_Camera_Init().

Parameters:

Camera_Handle

The handle for MAVIS camera, use the handle gotten from the

pHandle’ parameter of IMC_Camera_Init().

Output_Port: The Output Port to be configured. The Ports can

be:

OUTPUT_PORT_0,

OUTPUT_PORT_1,

OUTPUT_PORT_2 and OUTPUT_PORT_3

Signal_Source

The hardware Signal Source for Output Port and the sources

can be:

INTEGRATE_ENABLED_SIGNAL

(0x00),

TRIGGER_READY_SIGNAL

(0x01),

USER_SET_SIGNAL

(0x03)

STROBE_SIGNAL (0x04)

-

77

-