Power supply/fan assembly overview, 37 4/32b san switch power supply/fan assembly unit – IBM AA-RWF3A-TE User Manual

Page 106

Advertising
background image

Replacing the 4/32B SAN Switch Power Supply/Fan

Assembly Unit

Read this section for Power Supply/Fan Assembly Unit replacement procedures.

Power Supply/Fan Assembly overview

The 4/32B SAN Switch fans are fixed inside the integrated power supply/fan FRU

to provide necessary airflow to cool the whole system. There is one fan located in

the rear section of each FRU. The system software sets fan speed and measures their

speeds through the tachometer interface.
The two power supply/fan assembly FRU units are hot-swappable if replaced one at a

time. They are identical and fit into either slot. Fabric OS identifies the power supplies

from left to right on the port side as PS1 (on the left) and PS2 (on the right).
The Fabric OS identifies the Power Supplies as follows (viewing the switch from the

port side):

PS1 on the left

PS2 on the right

Figure 37

identifies Power Supply/Fan Assembly Unit components.

25275a

1

2

3

4

5

6

1. Power Supply/Fan Assembly Unit

2. AC power switch

3. Status LED

4. Captive screw

5. Power cord inlet

6. Power cord retainer

Figure 37 4/32B SAN Switch Power Supply/Fan Assembly Unit

106

Installing field-replaceable units