Securing the switch to the outer rails, Securing the switch to the, Outer rails – IBM AA-RWF3A-TE User Manual

Page 50

Advertising
background image

NOTE:
Figure 17

illustrates how to attach the plenum to the 4/8 or 4/16 SAN Switch

specifically. If installing the plenum on the 4/32B SAN Switch, the procedure and

figure also applies.

IO

IO

I

!

25052a

1

2

AT

TE

NT

IO

N:

M

axim

um

scr

ew

le

ng

th

fo

r ra

ck

m

ou

nt

ing

to

be

5m

m

o

r 1

3/6

4 in

.

3

Figure 17 Attaching the Plenum to the 4/8 or 4/16 SAN Switch

1. Plenum

2. SAN Switch

3. Two screws for attaching plenum to rails

Securing the switch to the outer rails

To secure the switch to the outer rails:

1.

Insert the switch with the attached inner rails into the outer rails.

NOTE:

This step applies to installing a switch in HP 9000 Series, HP 10000

Series or HP System/e racks.

2.

Insert the device into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head

screws with captive star lock washers with one on each side. See

Figure 18

and

Figure 19

.

50

Installing and configuring SAN Switches

Advertising