Table 14

describes the 4/32 SAN Switch nonport side LEDs.

Table 14 4/32 SAN Switch nonport side LED patterns

LED name

LED color

Hardware status

Recommended action

No light

Power supply is not receiving

power or power is off.

Verify that the power supply is on

and seated and the power cord is

connected to a functioning power

source.

Steady green

Power supply is operating

normally.

No action required.

Power Supply

Status

Steady amber

(for more than

5 seconds)

Power supply fault for one of

the following reasons:
Power cable is disconnected.
Power supply is off.
Power supply has failed.

Try the following:
Check the power cable connection.
Verify that the power supply is

powered on.
Replace the power supply.

No light

Fan assembly is not receiving

power.

Verify that the fan assembly is seated

in the switch.

Steady green

Fan assembly is operating

normally.

No action required.

Fan Status

Steady amber

(for more than

5 seconds)

One or more of the fans in the

fan assembly failed or the fan

FRU was disabled by the user.

Verify that the fan FRU is enabled.

If the fan FRU is enabled, the FRU is

faulty and should be replaced.

4/64 SAN Switch port side LEDs

The 4/64 SAN Switch integrates the following port side LEDs:

System Status LED

Power Status LED

Two Ethernet Port LEDs

One Port Status LED

Port Speed LED for each port on the switch. These LEDs are displayed below

each pair of Fibre Channel ports. The LEDs are located in the array in the same

relative positions as the ports.

Figure 26

on page 80 identifies the LEDs on the port side of the switch.

Table

15

on page 81 describes the port side LED patterns.