Items required, 18 4/32 san switch power supply status leds – IBM AA-RWF3A-TE User Manual

Page 93

Advertising
background image

Table 18 4/32 SAN Switch Power Supply Status LEDs

LED color

Meaning

Corrective action

No light

The power supply is not receiving

power or is off.

Verify that the power supply is on and seated

and that the power cord is connected to a

functioning power source.

Steady green

Power supply is operating

normally.

No action required.

Steady amber

for more than 5

seconds

Power supply fault for one of the

following reasons:
Power cable is disconnected.
Power supply is off.
Power supply has failed.

Try the following:
Check the power cable connection.
Verify that the power supply is powered on.
Replace the power supply.

Items required

Replacing a 4/32 SAN Switch power supply should take less than two minutes and

requires the following items:

New power supply

Phillips #1 screwdriver

SAN Switch installation guide

93