SRP_USER_CODE

The abend occurred while running user application
code.

SRP_PPT_ENTRY

The abend occurred while running
SRP_ERROR_PPT_NAME. If this flag is not set,
the abend occurred while running
SRP_ERROR_STACK_NAME.

SRP_VALID_OFFSET

A meaningful offset could be determined.

SRP_VALID_REASON

MVS has supplied a reason code for the abend.

SRP_NOT_CICS_RB

CICS RB was not in control at the time of the
abend (that is, the abend occurred in a system
service invoked by CICS).

SRP_CICS_ERROR_REASON

4-character field containing the MVS abend reason code. It
contains a value only if flag SRP_VALID_REASON is set.

SRP_CICS_ERROR_DATA

An area describing the last thing that CICS did, prior to the
abend. It contains the following:

SRP_CICS_EC_PSW

8-character field containing the extended control
(EC) mode program status word (PSW)

SRP_CICS_EC_INT

8-character field containing the interrupt code and
ILC

SRP_CICS_REGST

64-character field containing the contents of the
general-purpose (GP) registers

SRP_CICS_EXEC_KEY

1 byte containing the PSW key, in the form X'0n'.

SRP_SYSTEM_ERROR_DATA

An area describing the last thing “the system” did, prior to
the abend. It contains the following:

SRP_SYSTEM_EC_PSW

8-character field containing the EC mode PSW

SRP_SYSTEM_EC_INT

8-character field containing the interrupt code and
ILC

SRP_SYSTEM_REGST

64-character field containing the contents of the GP
registers

SRP_SYSTEM_EXEC_KEY

1 byte containing the PSW key, in the form X'0n'.

system recovery program exit