DEVICE
==> 3650
SESSIONTYPE
==> USERPROG
BRACKET
==> NO
RELREQ
==> NO
DISCREQ
==> NO
RECEIVESIZE
==> 256
IOAREALEN
==> 256
ATI
==> YES
TTI
==> YES
BIND SENT BY CICS :
01040430 30400000 00000080 00000000
******************************************************************
13) 8815 SCANMASTER (APPC SINGLE SESSION)
******************************************************************
SIN62 MODEENT LOGMODE=SIN62,
8815 SCANMASTER.
TYPE=0,
FMPROF=X'13',
TSPROF=X'07',
PRIPROT=X'B0',
SECPROT=X'B0',
COMPROT=X'50B1',
PSNDPAC=X'00',
SRCVPAC=X'00',
SSNDPAC=X'00',
RUSIZES=X'8585',
PSERVIC=X'060200000000000000002C00'
TERMINAL definition
*************************
AUTINSTNAME ==> MLU62
AUTINSTMODEL ==> ONLY
GROUP
==> PDATD
TYPETERM
==> SINLU62
INSERVICE
==> YES
TYPETERM definition
*************************
TYPETERM
==> SINLU62
GROUP
==> PDATD
DEVICE
==> APPC
RECEIVESIZE ==> 2048
SENDSIZE
==> 2048
ATI
==> YES
TTI
==> YES
Note: There is no RDO keyword equivalent of the MACRO
keyword 'FEATURE=SINGLE', because this is assumed with
RDO DEFINE TYPETERM when DEVICE=APPC.
BIND SENT BY CICS :
001307B0 B050B100 00858580 00060200
00000000 0000002C 00000800 00000000
0000001D 00090240 40404040 40404009
03006765 71D98A6C 300704C3 C9C3E2E6
F1000000 00000000 00000000 00000000
******************************************************************
14) 3290 (SDLC)
******************************************************************
S3290
MODEENT LOGMODE=S3290,
3290 SDLC
TYPE=1,
FMPROF=X'03',
TSPROF=X'03',
PRIPROT=X'B1',
SECPROT=X'90',
COMPROT=X'3080',
RUSIZES=X'8787',
PSERVIC=X'02800000000018503EA07F00'
TERMINAL definition
*************************
AUTINSTNAME
==> M3290
matching models and LOGON mode entries
784
CICS TS for OS/390: CICS Customization Guide