IBM SC33-1683-02 User Manual

Page 31

Advertising
background image

The following global user exits became obsolete:

– XDBDERR

– XDBFERR

– XDBIN

– XDBINIT

– XJCWB

– XJCWR

– XKCREQ

– XRCFCER

– XRCOPER

– XTSIN

– XTSOUT

– XTSREQ

v

Changes to task-related user exits:

“Chapter 2. Task-related user exit programs” on page 249 describes how
task-related user exits can be invoked for SPI calls; and, if CICS is in-doubt
about the outcome of a unit of work, can be told to wait rather than to take a
forced decision.

v

Changes to the exit programming interface (XPI):

The following new XPI function calls were introduced:

– INQUIRE_PARAMETERS

– SET_PARAMETERS

The following existing XPI calls were modified—that is, new options were added,
or obsolete options removed:

– INQUIRE_SYSTEM

– INQUIRE_TRANDEF

– INQUIRE_TRANSACTION

– SET_SYSTEM

– WRITE_JOURNAL_DATA

v

Extensions to the interface to the autoinstall user program:

Two new chapters were added:

“Chapter 13. Writing a program to control autoinstall of shipped terminals” on

page 523

“Chapter 14. Writing a program to control autoinstall of Client virtual terminals”

on page 531.

Also, “Chapter 12. Writing a program to control autoinstall of APPC connections”

on page 513 was extended, to describe extensions for generic resource support.

v

The CICS log manager:

“Chapter 23. CICS logging and journaling” on page 629 was rewritten and
extended to describe the functions of the new CICS log manager.

v

Miscellaneous changes:

“The shutdown assist utility program, DFHCESD” on page 395 describes the

utility program that replaces the DFH$SDAP program of CICS/ESA® 4.1.

Summary of changes