Parts listing, Parts, Listing – IBM Partner Pavilion DS4100 User Manual

Page 147

Advertising
background image

Table

17.

Symptom-to-FRU

index

(continued)

Problem

indicator

Component

Possible

cause

Possible

solutions

The

DS4000

Storage

Manager

client

Enterprise

Management

window

sees

each

storage

server

controller

as

an

independent

storage

subsystem

or

a

partially

managed

device.

Controller

No

drives

are

present

in

the

storage

server.

Ensure

that

at

least

one

drive

is

present

in

the

storage

server

so

that

it

can

be

configured

properly.

One

controller

was

replaced

incorrectly.

The

controller

firmware

versions

probably

failed

to

synchronize

correctly.

To

recover,

perform

the

following

steps:

1.

Remove

and

reinsert

the

controller

blade.

2.

Wait

5

minutes.

3.

Delete

the

controller

entry

with

the

incorrect

firmware

version

from

the

DS4000

Storage

Manager

Enterprise

Management

window.

4.

Add

the

controller

back

to

the

DS4000

Storage

Manager

Enterprise

Management

window

using

the

Add

Device

menu

option

in

the

Enterprise

Management

window.

5.

If

the

DS4000

Storage

Manager

client

Enterprise

Management

window

still

shows

each

storage

server

controller

as

an

independent

storage

subsystem

or

a

partially

managed

device,

repeat

this

procedure.

If

the

problem

still

persists,

contact

IBM

support.

Note:

If

you

cannot

find

the

problem

in

the

Symptom-to-FRU

index,

test

the

entire

system.

Parts

listing

Figure

79

on

page

116

and

the

following

table

provide

a

parts

listing

for

the

DS4100.

Chapter

6.

Hardware

maintenance

115