Page 54: Rails, Rear, Rack, Mounting, Template, Figure, Ds4100

Advertising
background image

Installing

the

support

rails

Before

installing

the

DS4100

in

a

rack

cabinet,

you

must

install

the

rails

and

rack-mounting

hardware

that

come

with

your

storage

server.

The

DS4100

requires

an

Electronic

Industries

Association

(EIA)

310-D

Type

A

19-inch

rack

cabinet.

The

distance

between

EIA

rails,

from

the

front

to

the

rear

of

the

rack

cabinet,

is

60.96

cm

(24

in.)

minimum

and

81.28

cm

(32

in.)

maximum.

This

rack

cabinet

conforms

to

the

EIA

standard.

Where

you

place

the

support

rails

in

the

rack

cabinet

depends

on

where

you

intend

to

position

the

storage

server.

Complete

the

following

steps

to

install

the

support

rails:

Note:

Refer

to

Figure

12

on

page

24

while

performing

these

steps.

1.

Ensure

that

the

rack

cabinet

has

already

been

installed.

2.

Ensure

that

a

stabilizer

has

been

correctly

attached

to

the

bottom

front

of

the

rack

cabinet

to

prevent

the

rack

cabinet

from

tipping

forward

while

the

DS4100

is

being

installed.

Refer

to

the

installation

and

service

guide,

or

equivalent,

for

the

rack

cabinet

as

required.

3.

Locate

the

two

support

rails

and

six

of

the

eight

M6

screws

that

are

supplied

with

the

DS4100.

Rack Mounting

Template

REAR

Printed in the U.S.A.

®

Rail assembly
(

)

Rear Left

Rail assembly

(

)

Rear Right

DS4100

3 U

2 U

1 U

0 U

3 U

2 U

1 U

0 U

f10ug059

Figure

10.

Rear

rack

mounting

template

22

IBM

TotalStorage

DS4100

Storage

Server:

Installation,

User’s,

and

Maintenance

Guide