Turning on the storage server, Turning, Storage – IBM Partner Pavilion DS4100 User Manual

Page 98: Server

Advertising
background image

Turning

on

the

storage

server

Important:

DS4100

base

storage

server

only:

You

must

turn

on

the

storage

expansion

units

and

verify

that

the

storage

expansion

unit

fibre

channel

connections

are

optimal

by

checking

the

indicator

lights

before

you

turn

on

the

DS4100.

The

controllers

might

not

recognize

the

correct

configuration

if

the

hard

disk

drives

are

powered

up

after

the

DS4100.

For

instructions

on

how

to

power

up

the

storage

expansion

units,

refer

to

the

storage

expansion

unit

documentation.

Note:

Always

wait

at

least

30

seconds

between

the

time

you

turn

off

a

power

switch

and

the

time

you

turn

on

the

power

again.

Perform

the

following

steps

to

turn

on

the

power

for

the

initial

startup

of

the

storage

server:

1.

Verify

that:

a.

All

communication

and

power

cables

are

plugged

into

the

back

of

the

storage

server

and

a

properly

grounded

ac

electrical

outlet.

b.

All

hard

disk

drives

are

locked

securely

in

place.

For

more

information,

see

“Installing

hot-swap

hard

disk

drives”

on

page

80.

Note:

At

least

one

drive

must

be

present

before

you

start

the

DS4100.

Attention:

If

you

are

restarting

the

system

after

a

normal

shutdown,

wait

at

least

10

seconds

before

you

turn

on

the

power

by

using

the

power-on

sequence

in

step

2.

2.

Check

the

system

documentation

for

the

hardware

devices

that

you

intend

to

power

up,

and

then

determine

the

proper

startup

sequence.

Use

the

following

power-on

sequence,

where

applicable:

a.

Turn

on

the

power

to

the

supporting

devices

(for

example,

Ethernet

switches

and

management

stations)

before

the

storage

server.

Attention:

If

you

will

be

directly

managing

the

storage

array,

you

must

set

up

the

Dynamic

Host

Configuration

Protocol

(DHCP)

or

BOOT-P

server

before

you

turn

on

the

power.

Setting

up

the

server

allows

the

controllers

to

obtain

the

corresponding

IP

address

when

you

turn

on

the

power

to

the

array

module.

For

more

information,

see

the

software

installation

guide

for

your

operating

system.

b.

You

must

turn

on

the

expansion

units

before

the

storage

server.

The

controllers

might

not

recognize

the

correct

configuration

if

the

drives

are

powered

up

after

the

storage

server.

For

instructions

on

how

to

power

up

the

expansion

units,

see

the

expansion-unit

documentation.

c.

Turn

on

the

power

to

the

storage

server;

then

restart

or

turn

on

the

power

to

the

host.

Note:

Depending

on

your

operating

system,

you

might

not

have

to

restart

the

host.

For

more

information,

see

the

software

installation

guide

for

your

operating

system.

3.

Turn

on

the

power

to

each

device,

based

on

the

power-on

sequence

in

step

2.

To

turn

on

power

to

the

storage

server,

turn

on

the

power-supply

switches

on

the

back

of

the

storage

server.

You

must

turn

on

both

power-supply

switches

to

take

advantage

of

the

redundant

power

supplies.

4.

Use

the

DS4000

Storage

Manager

client

and

the

Fault

LEDs

to

check

the

overall

status

of

the

storage

server

and

its

components.

All

LEDs

should

be

66

IBM

TotalStorage

DS4100

Storage

Server:

Installation,

User’s,

and

Maintenance

Guide