IBM xSeries 330 User Manual

Page 10

Advertising
background image

2

Hardware Maintenance Manual: xSeries 330

•

Power-on the computer.

•

If the computer hangs and no error is displayed, go to “Undetermined
problems” on page 98.

•

Record any POST error messages displayed on the screen. If an error is
displayed, look up the first error in the “POST error codes” on page 90.

•

Check the information LED panel System Error LED; if on, see “Information
panel system error LED” on page 85.

•

Check the System Error Log. If an error was recorded by the system, see
“Chapter 7. Symptom-to-FRU index,” on page 83.

•

Start the Diagnostic Programs. See “Diagnostic programs and error
messages” on page 15.

•

Check for the following responses:

a.

One beep.

b. Readable instructions or the Main Menu.

3.

DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?

NO.

Find the failure symptom in“Chapter 7. Symptom-to-FRU index,” on page 83.

YES.

Run the Diagnostic Programs. If necessary, refer to “Starting the diagnostic

programs” on page 16.
If you receive an error, go to“Chapter 7. Symptom-to-FRU index,” on page 83.

If the diagnostics completed successfully and you still suspect a problem, see
“Undetermined problems” on page 98.