background image

50

Hardware Maintenance Manual: xSeries 330

6.

Check the hard disk drive status indicators to verify that the hard disk drives are
operating properly. (See “Server controls and indicators” on page 6 for the
location of the status indicators.)

•

When the green light flashes rapidly (three flashes per second), the controller
is identifying the drive.

Replacing a hard disk drive is done in the same manner as installing a new hard disk
drive.

If the server has a Redundant Array of Independent Disks (ServeRAID) adapter
installed, you can hot-swap drives. For more information about hot-swapping drives
refer to the documentation provided with the ServeRAID adapter, “Hot-swap disk
drives”,
and to the notes under “Hard disk drives” on page 48.

Hot-swap disk drives

Your server can be configured with hardware to let you continue to operate your
system while removing or installing hard disk drives (or hot-swapping). To do this
you need a ServeRAID adapter, hard disk drive, and the hard disk drive tray.

•

Each hard disk drive that you plan to install must have an accompanying hard
disk drive tray.

•

The drive must be a low-voltage differential drive (LVD), and have a single
connector attached (SCA) connector.

•

The hard disk drive bays connect to a SCSI backplane. This backplane is the
printed circuit board behind the bay and is connected to the ServeRAID adapter.

•

The backplane controls the SCSI IDs for the hard disk drives.

Preinstallation steps

Before you install a hard disk drive, review the following.

•

Inspect the drive tray for any signs of damage.

•

Ensure that the drive is installed properly in the tray.

•

To maintain proper system cooling, do not operate the server for more than two
minutes without either a drive or a filler panel installed in each bay.

•

If your server has a ServeRAID adapter installed; refer to the documentation
provided with the ServeRAID adapter for information about adding a drive.

•

Read the safety precautions listed in “Safety information” on page 107, “Handling
electrostatic discharge-sensitive devices” on page 110.

•

Check the instructions that come with the drive to see if you need to set any
switches or jumpers on the drive.

Installing hot-swap disk drives

Note:

The illustrations in this document might differ slightly from your hardware.

Advertising