If you do not set this field, the autoinstall routine uses the language defined in
the model, if one is specified. However, when control is passed to the program,
CICS determines the language from the program itself, and overrides any
specification provided.

You should not need to specify the language of executable programs that have
been translated using the EXEC CICS translator before compiling.

PGAC_CEDF_STATUS

allows you to specify, in a 1-byte field, the execution diagnostic facility (EDF)
status of the program to be autoinstalled. The equated values are:

PGAC_CEDF_YES

EDF can be used with this program.

PGAC_CEDF_NO

EDF cannot be used with this program.

PGAC_DATA_LOCATION

allows you to specify, in a 1-byte field, the data location for task-lifetime storage.
The equated values are:

PGAC_LOCATION_BELOW

Task-lifetime storage must be located below 16MB.

PGAC_LOCATION_ANY

Task-lifetime storage can be below or above 16MB.

PGAC_EXECUTION_KEY

allows you to specify, in a 1-byte field, the execution key for the program. The
equated values are:

PGAC_CICS_KEY

The program is to execute in CICS key.

PGAC_USER_KEY

The program is to execute in user key.

PGAC_LOAD_ATTRIBUTE

allows you to specify, in a 1-byte field, the load attributes for the object. The
equated values are:

PGAC_RELOAD

CICS is to load a fresh copy of the object for each request.

PGAC_RESIDENT

CICS is to make the object permanently resident.

PGAC_TRANSIENT

The storage for this object is to be released whenever the use count
reaches zero.

PGAC_REUSABLE

CICS can use any copy of the object currently in storage.

PGAC_USE_LPA_COPY

allows you to specify, in a 1-byte field, whether CICS is to use an LPA-resident
copy of the program. The equated values are:

PGAC_LPA_YES

CICS is to use a copy from the LPA.

PGAC_LPA_NO

CICS is to load a private copy from its own DFHRPL or dynamic
LIBRARY concatenation.