IBM SC34-6814-04 User Manual
Page 864

ATI
==> YES
TTI
==> YES
AUTOCONNECT
==> NO
LOGONMSG
==> YES
BIND SENT BY CICS depends on PSERVIC value on LOGMODE definition above:
EITHER
:
01020271 40200000 00000080 00000000
00000000 00000002 00009300 00300000
OR
:
01020271 40200000 00000080 00000000
00000018 502B507F 00009300 00300000
OR
:
01020271 40200000 00000080 00000000
Real Model 2
00000018 5000007E 00009300 00300000
******************************************************************
2) LOCAL SNA 3277/78/79 (without special features) LUTYPE2
******************************************************************
S32782
MODEENT LOGMODE=S32782,
SNA LUTYPE2 3270
TYPE=1,
FMPROF=X’03’,
TSPROF=X’03’,
PRIPROT=X’B1’,
SECPROT=X’B0’,
COMPROT=X’3080’,
RUSIZES=X’8585’,
PSERVIC=X’028000000000185018507F00’
TERMINAL definition
*************************
AUTINSTNAME
==> M32782
AUTINSTMODEL
==> ONLY
GROUP
==> PDATD
TYPETERM
==> T32782
INSERVICE
==> YES
TYPETERM definition
*************************
TYPETERM
==> T32782
GROUP
==> PDATD
DEVICE
==> LUTYPE2
TERMMODEL
==> 2
LIGHTPEN
==> YES
AUDIBLEALARM
==> YES
UCTRAN
==> YES
IOAREALEN
==> 256,256
ERRLASTLINE
==> YES
ERRINTENSIFY
==> YES
USERAREALEN
==> 32
ATI
==> YES
TTI
==> YES
LOGONMSG
==> YES
DISCREQ
==> YES
RECEIVESIZE
==> 256
BUILDCHAIN
==> YES
BIND SENT BY CICS :
010303B1 B0308000 0085C780 00028000
00000018 5018507F 00000000 00000000
******************************************************************
3) 3770 BATCH LU (3777)
******************************************************************
BATCH
MODEENT LOGMODE=BATCH,
3770 BATCH
TYPE=1,
FMPROF=X’03’,
TSPROF=X’03’,
PRIPROT=X’B1’,
SECPROT=X’B0’,
COMPROT=X’7080’,
PSERVIC=X’01310C70E100D20000E100D0’