Adjustments, Regulators adjustments, Adjusting dispensing valves water flow rate – Cornelius VANTAGE POST-MIX DISPENSER User Manual

Page 14

Advertising
background image

10

312031004

2. Check the dispensing valves for dripping that indicates leakage and repair as necessary.

ADJUSTMENTS

CO

2

REGULATORS ADJUSTMENTS

WARNING: CO

2

displaces oxygen. Strict attention must be observed in the prevention of

CO

2

(carbon dioxide) gas leaks in the entire CO

2

and soft drink system. If a CO

2

gas leak is

suspected, particularly in a small area, immediately ventilate the contaminated area before

attempting to repair the leak. Personnel exposed to high concentration of CO

2

gas will experience

tremors which are followed rapidly by loss of consciousness and suffocation.

NOTE: To readjust CO

2

regulator to a lower setting, loosen adjusting screw lock nut, then turn screw to

the left (counterclockwise) until pressure gage reads 5 psi lower than new setting will be. Turn the

adjusting screw to the right (clockwise) until the gage registers new setting, then tighten the lock nut.

Adjusting Carbonator CO

2

Regulator.

UNIT WITH INTEGRAL (BUILT-IN) COLD CARBONATOR

Adjust CO

2

regulator for the Unit integral (built-in) carbonator at 60-psi maximum.

UNIT REQUIRING REMOTE CARBONATOR

Adjust CO

2

regulator for the remote carbonator to CO

2

pressure specified in manual provided with the

carbonator.

Adjusting Syrup Source CO

2

Regulator.

SUGAR SYRUP TANKS CO

2

REGULATOR

Adjust syrup tanks CO

2

regulator to a minimum of 45-psi.

SYRUP PUMPS (BAG-IN-BOX SYSTEM)

Adjust the syrup pumps CO

2

regulator to 70-psi. DO NOT EXCEED MAXIMUM CO

2

PRESSURE SPECIFIED

ON THE SYRUP PUMPS.

ADJUSTING DISPENSING VALVES WATER FLOW RATE

(see Figure 8)

1. Remove cover from the dispensing valve by lifting the front cover up 1/4 inch and pulling forward.

2. Install syrup diversion tube assembly on the dispensing valve by pushing rubber end of the syrup diversion

tube onto the syrup outlet of the inner nozzle.

3. Measure the water flow rate by dispensing water into a graduated cup for a set period of time.

NOTE: Adjusting screw stops are built into the valve to prevent leakage when the screws are adjusted

too far clockwise. Stop adjusting clockwise when turning resistance increases. Turn the screw

counterclockwise 1--1/2 turns after the stop are contacted.

4. Turn the water flow regulator adjusting screw to the left (counterclockwise) to decrease the water flow rate

or turn the adjusting screw to the right (clockwise) to increase the water flow rate, then recheck the flow

rate. Adjustments should be no more than 1/4 turn at a time.

5. Remove syrup diversion tube from the dispensing valve, then install cover on the dispensing valve.