Trouble

Remedy

Probable Cause

DISPENSED PRODUCT

PRODUCES FOAM AS IT

LEAVES DISPENSING VALVE.

(cont’d)

F.

Dirty water supply.

F.

Check water filter. Replace

cartridge (see NOTE).

NOTE: If water supply is dirty, be sure to flush lines and

carbonator carbonated water tank completely. It may be necessary

to remove lines to the carbonated water tank, invert the tank, then

flush tank and all inlet lines to remove any foreign particles or dirt.

NO PRODUCT DISPENSED

FROM ALL DISPENSING

VALVES

A. No electrical power to Unit.

A. Plug in Unit power cord or check

for blown power fuse or tripped

circuit breaker. (Note: Fuse or

circuit breaker are not part of

Unit.)

B. Disconnected dispensing

valves power cord.

B. Connect dispensing valves power

cord.

C. Disconnected or broken wiring

to dispensing valveS.

C. Connect or replace wiring.

D. Inoperative 115 /24 VAC

transformer.

D. Replace transformer.

ONLY CARBONATED WATER

DISPENSED.

A. Out of syrup

A. Replenish syrup supply as

instructed.

B. Inoperable dispensing valve.

B. Repair dispensing valve.

C. Dispensing valve syrup flow

control not properly adjusted.

C. Adjust dispensing valve syrup

flow control (Water-to-Syrup

‘‘Ratio’’) as instructed.

D. Dispensing valve syrup flow

control or syrup lines

restricted.

D. Sanitize syrup system as

instructed.

ONLY SYRUP DISPENSED.

A. Plain water inlet supply line

shutoff valve closed.

A. Open plain water inlet supply line

shutoff valve.

B. Carbonator not operating.

B. Repair carbonator.

TROUBLESHOOTING REFRIGERATION SYSTEM

COMPRESSOR DOES NOT

OPERATE.

A. Ice bank sufficient.

A. Refrigeration not called for.

B. Ice bank control board has

2-minute time delay.

B. Wait 2-minutes for compressor to

start.

C. Unit power cord unplugged or

drop-in refrigeration assembly

power cord unplugged.

C. Plug in Unit power cord or plug in

refrigeration assembly power

cord.

D. No power source (blown fuse

or tripped circuit breaker).

D. Replace fuse or reset circuit

breaker. (Note: Fuse or circuit

breaker are not part of Unit.)

E. Low voltage.

E. Voltage must be at least 103 volts

at compressor terminal when

compressor is trying to start.

F.

Loose, disconnected, or

broken wiring.

F.

Tighten connections or replace

broken wiring.