19

312031004

TROUBLESHOOTING

IMPORTANT: Only a qualified Service Person should service internal components or electrical wiring.

DANGER: Disconnect electrical power to the Unit to prevent personal injury before

attempting any electrical repairs to the internal components. If repairs are to be made to

one of the syrup systems, disconnect syrup supply from the system, then bleed system

pressure before proceeding. If repairs will be made to the CO

2

or the carbonated water system,

disconnect electrical power to the carbonator, shut off CO

2

and plain water supplies, then bleed

systems pressures before proceeding.

TROUBLESHOOTING UNIT

Trouble

Probable Cause

Remedy

WATER-TO-SYRUP ‘‘RATIO’’

TOO LOW OR TOO HIGH.

A. Dispensing valve syrup flow

regulator not properly

adjusted.

A. Adjust Water-to-Syrup ‘‘Ratio’’as

instructed.

B. Syrup Tanks System.

CO

2

gas pressure to syrup

tanks insufficient to push syrup

out of tank.

Bag-In-Box System.

CO

2

gas pressure to syrup

pumps insufficient to operate

pumps.

B. Adjust CO

2

regulator for syrup

tanks as instructed.

Adjust syrup pumps CO

2

regulator

as instructed.

ADJUSTMENT OF

DISPENSING VALVE SYRUP

FLOW REGULATOR DOES

NOT INCREASE TO DESIRED

WATER-TO-SYRUP ‘‘RATIO’’

A. No syrup supply.

A. Replenish syrup supply.

B. Syrup Tanks system.

Syrup tanks CO

2

regulator out

of adjustment.

Syrup Bag-In-Box System.

Syrup pumps CO

2

regulator

out of adjustment.

B. Adjust CO

2

regulator for syrup

tanks as instructed.

Adjust syrup pumps CO

2

regulator

as instructed.

C. Dispensing valve syrup flow

control or syrup line restricted.

C. Sanitize syrup system as

instructed.

D. Improper syrup Baume.

D. Replace syrup supply.

E. Inoperative dispensing valve

syrup flow control.

E. Repair dispensing valve syrup

flow control.

F.

Tapered gasket inside tube

swivel nut connection distorted

from being overtightened

restricting syrup flow.

F.

Replace tapered gasket. Make

sure it is properly seated.

Advertising