Cornelius VANTAGE POST-MIX DISPENSER User Manual

Page 15

Advertising
background image

11

312031004

WATER FLOW

REGULATOR

SYRUP FLOW

REGULATOR

INNER NOZZLE

NOZZLE

SYRUP DIVERSION

TUBE

RATIO CUP

Counterclockwise

to Decrease

Clockwise

to Increase

FIGURE 8. UF-1 DISPENSING VALVE

ADJUSTING WATER-TO-SYRUP “RATIO” (BRIX) OF DISPENSED PRODUCT

(see Figure 8)

NOTE: Make sure the dispensing valve water flow rate is as desired before adjusting the valve for

Water-to-Syrup ‘‘Ratio’’(Brix) of the dispensed product.

Adjust Water--to--Syrup “Ratio”(Brix) of the dispensed product by using ratio cup (P/N 311100000) and syrup

diversion tube assembly (P/N 319540000) as follows:

1. Remove cover from the dispensing valve by lifting front cover up 1/4 inch and pulling forward.

2. Install syrup diversion tube assembly on the dispensing valve by pushing the rubber end of the syrup

diversion tube onto the syrup outlet of the inner nozzle.

Notice: Refer to syrup manufacturer’s recommendations on syrup package for water-to-syrup ratio.

3. Dispense enough to fill syrup diversion tube with syrup.

4. Hold large chamber of the ratio cup under the dispensing valve nozzle. Place free end of the syrup

diversion tube into the syrup chamber marked for the proper ratio. Dispense approximately 6 ounces of

water into the ratio cup. Water and syrup levels should be even in cup.

Note: Adjusting screw stops are built into the valve to prevent leakage when the screws are adjusted

clockwise too much. Stop adjusting clockwise when turning resistance increases. Turn the screw

counterclockwise 1--1/2 turns after the stop are contacted.

5. Adjusting Syrup Flow Regulator -- If water and syrup levels are uneven in the ratio cup, adjust by

turning the dispensing valve syrup flow regulator adjusting screw labeled SYRUP as follows.