Cornelius VANTAGE POST-MIX DISPENSER User Manual

Page 26

Advertising
background image

22

312031004

Trouble

Remedy

Probable Cause

COMPRESSOR DOES NOT

OPERATE.(CONT’D)

G. Inoperative overload protector

or start relay.

G. Replace inoperative part.

H. Inoperative ice bank control.

H. Replace ice bank control.

I.

Inoperative compressor.

I.

Replace compressor.

COMPRESSOR WILL NOT

STOP AFTER SUFFICIENT

ICE BANK IS PRODUCED.

A. Ice bank control probe

damaged.

A. Replace ice bank probe.

B. Ice bank control board

inoperative.

B. Replace ice bank control board.

COMPRESSOR OPERATES

CONTINUOUSLY BUT DOES

NOT FORM SUFFICIENT ICE

BANK.

A. Cooling capacity is exceeded

by over-drawing.

A. Reduce amount of drinks drawn

per given time.

B. Unit located in excessively hot

area or air circulation through

condenser coil is restricted.

B. Relocate Unit or check and if

necessary, clean condenser coil

as instructed.

NOTE: Ice bank freezes from bottom of evaporator upward. A

refrigerant leak or insufficient charge might show an ice bank at

bottom and not at the top of evaporator.
NOTE: If overload protector cuts out compressor, condenser fan

motor will continue to operate; otherwise; troubleshooting

condenser fan motor problems is same as for ‘‘COMPRESSOR

DOES NOT OPERATE’’paragraph plus the following:

CONDENSER FAN MOTOR

NOT OPERATING.

A. Jumper cord loose or

disconnected from motor or

terminal block. Broken wire in

cord.

A. Tighten connections or

replace cord.

B. Inoperative condenser

fan motor.

B. Replace condenser fan motor.

AGITATOR MOTOR NOT

OPERATING.

A. Unit power cord or

refrigeration assembly power

cord unplugged.

A. Connect power cord(s).

B. No power source (blown fuse

or tripped circuit breaker).

B. Replace fuse or reset circuit

breaker. (Note: Fuse or circuit

breaker are not part of Unit.)

C. Agitator motor propeller

obstructed.

C. Remove obstruction.

D. Low voltage.

D. Voltage must be at least 103 VAC

at compressor terminals when

compressor is trying to start.

E. Loose, disconnected, or

broken wiring.

E. Tighten connections or replace

broken wiring.

F.

Inoperative agitator motor.

F.

Replace agitator motor.