John Deere HR-BG5002 User Manual

Page 11

Advertising
background image

Operator’s Manual



Preparation

HOSe and ReGulaTOR

John Deere models are equipped with a hose and regulator with a

QCC

®

- Quick Closing Coupling.

The QCC

®

coupling contains a magnetic Flow Limiting Device which

will limit the flow of gas should there be a leak between the regulator

and the appliance valve. This device will activate if the cylinder valve

is opened while the appliance valves are open.

Be sure the appliance

valves are off before the cylinder valve is opened to prevent

accidental activation.
The QCC

®

coupling incorporates a heat sensitive hand wheel that will

cause the back check module in the QCC

®

cylinder valve to close when

exposed to temperatures between 40° and 00°F. Should this occur,

do not attempt to reconnect the nut. Remove hose/regulator assembly

and replace with a new one.
The pressure regulator is set at  inches WC (water column) and is

for use with LP gas only. The hose and hose couplings comply with

CGA Standard CAN 1.83. No modifications or substitutions should be

attempted.
Protect the hose from dripping grease and

dO nOT allow the hose to

touch any hot surface, including the base casting of the grill.
Inspect seal in the QCC

®

cylinder valve when replacing LP gas cylinder

or once per year whichever is more frequent. Replace seal if there is

any indication of cracks, creases, or abrasion.
Inspect hose before each use of the grill. If the hose is cracked,

cut, abraded or damaged in any way, the appliance must not be

operated.
For repair or replacement of hose/regulator assembly, contact your

dealer or approved service center.

CONNECTING REGULATOR TO LP-GAS CYLINDER:

. Be sure cylinder valve and appliance valves are “OFF’.
. Place full LP-Gas Cylinder on base mounting lip and secure top

collar as per assembly instructions.

. Center the nipple in the cylinder valve and hold in place.

Using other hand, turn the hand wheel clockwise until there is

a positive stop. Do not use tools. Hand tighten only. When

making the connection, hold the regulator in a straight line with

the cylinder valve, so as not to cross thread the connection.

(Fig. )

4. Leak test connections. See “Leak Testing”.
5. Refer to lighting instructions. To avoid activating the Flow

Limiting Device when lighting, open cylinder valve slowly with

the appliance valves off. If the Flow Limiting Device is

accidentally activated, turn off cylinder valve and appliance

valves, wait 0 seconds to allow the device to reset, open

cylinder valve slowly, then open the appliance valve.

Nipple with Flow

Limiting Device

Heat Sensitive

Hand-Wheel

Regulator

Check

Valve

Cylinder

Shut-Off

Valve

Fig. 

Advertising
This manual is related to the following products: