Preparation – John Deere HR-BG5002 User Manual

Page 9

Advertising
background image

Operator’s Manual

9

QCC

®

-1 QuICK ClOSInG COuPlInG

John Deere models are designed to be used with an LP-Gas

Cylinder equipped with the new QCC

®

- Quick Closing Coupling

system.

The QCC

®

- system incorporates new safety features required

by the American National Standards Institute (ANSI) and the

Canadian Standards Steering Committee.

• Gas will not flow until a positive connection has been

made.

• A thermal element will shut off the flow of gas between

40

°

and 00

°

F.

• When activated, a Flow Limiting Device will limit the

flow of gas to 10 cubic feet per hour.

lP-GaS CylIndeR

The lP-Gas Cylinder is not included with the Gas Grill. Be sure

to purchase one with the QCC

®

valve. This valve is recognized by

the external threads on the inlet port of the valve. QCC

®

equipped

cylinders are available from your local hardware stores or LP-Gas

dealer. (Fig. )

WaRnInG: any aTTeMPT TO COnneCT THe ReGulaTOR,

By uSe Of adaPTeRS OR any OTHeR MeanS,

TO any OTHeR ValVe COuld ReSulT In

daMaGe, fIRe OR InjuRy and May neGaTe

THe IMPORTanT SafeTy feaTuReS deSIGned

InTO THe QCC

®

-1 SySTeM.

SPECIFICATIONS:
. All LP-Gas Cylinders used with this appliance must be

constructed and marked with the specifications for LP-

Gas Cylinders in accordance with the Canadian Transport

Commission (CTC) for use in Canada, or the U.S. Department

of Transport (DOT) for use in the U.S.A.

. The LP-Gas Cylinder used for this appliance must not have a

capacity larger than 0 Ib. (9 kg). Approximately 8” (46cm)

high ” (cm) diameter.

. All LP-Gas Cylinders used with this appliance should be

inspected at every filling and re-qualified by a licensed service

outlet at the expiry date (0 years), in accordance with the DOT

(USA) and CTC (Canada) codes for LP-Gas Cylinders.

4. All LP-Gas Cylinders used with this appliance must be provided

with a shut-off valve terminating in a cylinder valve outlet No.

510, specified in the Standard for Compressed Gas Cylinder

Valve Outlet and Inlet Connection (USA) ANSI/CGA-V-1-1977

(Canada) CSA B96.

The cylinder supply system must be arranged for vapor

withdrawal. The cylinder must include a collar to protect the

cylinder valve. The cylinder valve must include a safety relief

device having direct communication with the vapor space of

the cylinder.

Preparation