Operator’s Manual

Preparation

leaK TeSTInG
All factory-made connections have been thoroughly tested for gas leaks.

However, shipping and handling may have loosened a gas fitting.

CauTIOn: TeST all fITTInGS fOR leaKS BefORe uSInG

yOuR GaS GRIll.

TeST THe CylIndeR ValVe fOR leaKS eaCH TIMe

THe CylIndeR IS fIlled.

TeST fOR leaKS eVeRy TIMe yOu COnneCT a GaS

fITTInG.

dO nOT SMOKe!

neVeR TeST fOR leaKS WITH a lIGHTed MaTCH

OR OPen flaMe.

TeST fOR leaKS OuTdOORS.

To test for leaks:
1. Extinguish any open flame or cigarettes in the area.
. Be sure that cylinder valve and appliance valves are “off’.
. Connect LP gas cylinder. See “Hose and Regulator”.
4. Prepare a soap solution of one part water, one part liquid

detergent.

5. With a full gas cylinder, open cylinder slowly.
6. Brush the soap solution on each connection. (Fig. 4 & 5)
7. If your grill is equipped with a side burner or rear burner:

a. Place finger tip over the opening in the orifice at the end of

hose.

b. Turn “SIDE”/“REAR” control to “HI”.

c. Brush soap solution on each connection between orifice and

control valve. (Fig. 6)

d. Turn “SIDE”/“REAR” control to “OFF”.

8. A leak is identified by a flow of bubbles from the area of the leak.
9. If a leak is detected, close the gas cylinder “shut-off’ valve, tighten

the connection and retest (Step 5).

0. If the leak persists, contact your grill dealer for assistance. Do not

attempt to operate appliance if a leak is present.