Example of Response camera.motion.auto_tracking(2).threshold.hsv&202

Accepted(camera.status=save)

Interpretation Change threshold of Intelligent Tracking. In VN-V686 before v1.02, this API is not available. 2 APIs

for setting HSV threshold and YUV threshold are availble. In case of HSV, H is from 0 to 180, S/V is from 0 to 255. In

case of RGB, R/G/B is from 0 to 255. The change is saved by the API, camera.status=save. If the change is not saved,

the setting is restored by reboot.

Allowed users admin, operator

Getting Dead Zone of Intelligent Tracking from VN-V685/686/686B

Format /api/param?camera.motion.auto_tracking(2).dead_zone

Example of response camera.motion.auto_tracking(2).dead_zone=40-40&200 OK

Interpretation Acquire dead zone of Intelligent Tracking. In VN-V686 before v1.02, this API is not available.

Motion smaller than dead zone is ignored by Intelligent tracking. Horizontal value is from 0 to 320, and vertical value is

from 0 to 240. Value in VGA is returned even if current resolution is QVGA.

Allowed users admin, operator, user

Setting Dead Zone of Intelligent Tracking for VN-V685/686/686B

Format /api/param?camera.motion.auto_tracking(2).dead_zone=data

Example of Response camera.motion.auto_tracking(2).dead_zone&202

Accepted(camera.status=save)

Interpretation Change dead zone of Intelligent Tracking. In VN-V686 before v1.02, this API is not available.

Motion smaller than dead zone is ignored by Intelligent tracking. Horizontal value is from 0 to 320, and vertical value is

from 0 to 240. Value in VGA is returned even if current resolution is QVGA. The change is saved by the API,

camera.status=save. If the change is not saved, the setting is restored by reboot.

Allowed users admin, operator

Getting Upper Limit of EZoom from VN-V685/686/686B

Format /api/param?camera.motion.zoom.digitallimit

Example of response camera.motion.zoom.digitallimit=2&200 OK

Interpretation Acquire upper limit of EZoom. 1, 2, 4, 8, 16 or 32 will be returned.

Allowed users admin, operator, user

Setting Upper Limit of EZoom for VN-V685/686/686B

Format /api/param?camera.motion.zoom.digitallimit=data

Example of Response camera.motion.zoom.digitallimit&202