Router Power Requirements

Table 54 on page 109 and Table 55 on page 109 list the AC and DC power system
electrical specifications for J-series Services Routers.

Table 54: AC and DC Power System Electrical Specifications for J2320 and J2350 Routers

Specification

Item

100 to 240 VAC nominal

AC input voltage

50 to 60 Hz

AC input line frequency

J2320 Services Routers: 3.2 A to 1.3 A

J2350 Services Routers: 3.5 A to 1.5 A

AC system current rating

–48 to –60 VDC operating range

DC input voltage

7.2 A

DC system current rating

Table 55: AC and DC Power System Electrical Specifications for J4350 and J6350 Routers

Specification

Item

100 to 240 VAC nominal

AC input voltage

50 to 60 Hz

AC input line frequency

J4350 Services Routers: 6 A

J6350 Services Routers: 8 A

AC system current rating

–48 to –60 VDC operating range

DC input voltage

20 A

DC system current rating