Creating a Benchmark Control Point

1. Position receiver on the control point.

NOTE: The StarFire 3000 receiver CANNOT be

moved during the creation of a Benchmark
Control Point. Any movement causes the
Benchmark to be inaccurate

2. From CONTROL POINT drop­down box (A), select

NEW.

3. Type in name of control point.

4. Enter mast height in the MAST HEIGHT input box (C).

If the implement receiver is used to set the control
point, the height dimension on a scraper is equal to
Implement Dimension C if blade is lowered to the
ground or Implement Dimension D if blade is fully
raised.

5. Select SET POINT button (B).

6. Select ENTER button (F).

A—CONTROL POINT

drop­down box

B—SET POINT button
C—MAST HEIGHT input box

D—CALIBRATE button
E—CLEAR button
F— ENTER button

PC13770

—UN—17MA

Y1

1

Calibrating to a Control Point

1. Position receiver on the control point.

NOTE: The StarFire 3000 receiver CANNOT be

moved during the calibration of a Benchmark
Control Point. Any movement causes the
calibration to be inaccurate.

2. Enter mast height (C) if it is at a different height than

when benchmark was set.

3. Select CALIBRATE button (D).

4. Select ENTER button (F).

A—CONTROL POINT

drop­down box

B—SET POINT button
C—MAST HEIGHT input box

D—CALIBRATE button
E—CLEAR button
F— ENTER button

PC13770