Setting snmp – JVC LST0728-001C User Manual

Page 142

Advertising
background image

134

Applications

When SNMP is enabled, the status of this unit can be
monitored from the SNMP manager of the surveillance
computer. The MIB extension information (JVCNVRMIB.txt)
must be registered to the SNMP manager.

1

Insert a commercially available flash memory
device into the serial terminal

2

Select [Unit Setting 2] from the main menu

[Main Menu List] Screen

3

Select the [Enable of SNMP] check box in the
[SNMP setting] section

● To use TRAP, select the [Enable of TRAP] check box in

the [SNMP setting] section.

● Refer to [List of TRAP Supported by this Unit]

(A Page 135) for the TRAP notifications supported by
this unit.

4

Enter the IP address of the surveillance
computer in the [SNMP manager’s address] field

5

Specify the SNMP community name

Example) kanshi1

Note :

● Up to 32 alphanumeric characters can be used for the

community name.

● TRAP signals may be missed on the receiving end

depending on the communication specifications. Operate
with judgement based on polling primarily and make use

of TRAP only secondarily.

6

Press [Copy extension MIB onto the flash
memory] in the [SNMP setting] section

● The MIB extension information is copied to a flash

memory device.

[Unit Setting 2] Screen

7

Register the MIB extension information to the
SNMP manager of the surveillance computer

● To register the MIB extension information to the

surveillance computer, refer to the instruction manual
of the SNMP manager.

8

Specify the surveillance (polling) settings for the
SNMP manager of the surveillance computer

● For details on how to set, refer to the instruction

manual of the SNMP manager.

● Refer to [List of Status that can be Obtained from this Unit]

(A Page 135) for the list of status that can be obtained
from this unit.

Setting SNMP

2

3

4

5

6

Advertising