Power connection – JVC OUTDOOR PTZ IP DOME CAMERA VN-V686WPU User Manual

Page 20

Advertising
background image

20

Connection/Installation

Note

● Be sure to use an AC 24 V supply that is

isolated from the primary power supply circuit.
Using a variable voltage power supply will
cause the camera and system to malfunction or
breakdown.

● The unit is to be powered by an AC 24 V power

supply. The AC 24 V power supply should
conform to the following: Class 2 only (For
USA), Isolated power supply only (For Europe
and others).

Connecting the power cable

Connects the camera to AC24V power.

When using 2-core VVF (Vinyl-insulated vinyl-
sheath cable), the connection distance is as
follows: (Reference value)

Memo

:

● After DHCP timeout, all IP addresses of VN-

V686WPU are set to 192.168.0.2 by default.

When the power of multiple cameras within the
same LAN environment are turned on at the
same time, the IP address of the cameras
overlap, thus preventing proper access. As
such, make sure to turn on the power of the
cameras one by one.

● In a system where multiple units of VN-

V686WPU are used, turn on the power of only
one unit to configure the IP address settings
using the Internet Explorer. Upon doing so, turn
on the power of the second unit and configure
accordingly. Configure the camera settings
using the same procedure.

● When overlapping of the IP address occurs,

check to ensure that there is only one VN-
V686WPU unit within the same LAN
environment, and wait for a while (at least 10
minutes) or power off and on all network
devices under the same LAN environment.
Otherwise, access to VN-V686WPU may fail.

Power Connection

Maximum
connection
distance

20 m

60 m

100 m

180 m

Conductor
Diameter
(mm)

R1.0
and
above

R1.6
and
above

R2.0
and
above

R2.6
and
above

To Power Supply

Solder welding or
crimping

Insulating
tape

Warning

● The rated power of this product is AC 24 V, 50

Hz/60 Hz. Make sure to use it with the correct
voltage.

● Supplying a power beyond the rated value

may result in failures, smoke or fire. When the
camera breaks down, turn off the power and
contact our service center immediately.

● When a power beyond the rated value is

supplied, the internal components may be
damaged even if no abnormality is found on
the appearance and operation of the camera.
Please contact your nearest JVC dealer
immediately for servicing (charged
separately).

VN-V686WPU_EN.book Page 20 Tuesday, December 25, 2007 11:23 AM