2 edge pre-select trigger mode (ep, At-140ge – JAI AT-140GE User Manual

Page 43

Advertising
background image

AT-140GE

- 41 -

9.7.2 Edge Pre-select Trigger Mode (EPS)
An external trigger pulse initiates the capture, and the exposure time (accumulation time) is

the fixed shutter speed set by programmable exposure or Exposure Time Abs. The

accumulation can be automatically set either LVAL synchronous or LVAL asynchronous in

relation to FVAL and trigger timing.

The resulting video signal will start to be read out after the selected shutter time.

For timing details, refer to fig35 . through fig43 .
To use this mode:

Set function:

Exposure mode

Edge pre-select

Pixel format

RGB8, 10V1, 10V2

Partial scan

Fast dump ON, ROI

Vertical binning

Binning vertical ON

Shutter mode

Programmable, Exposure Time Abs

GPIO setting

Important notes on using this mode

 Active Trigger pulse >2 LVAL to <1 FVAL
 Minimum Trigger interval is shown in the following table.

Mode

Minimum trigger interval

LVAL Sync

1056L + 3L

LVAL Async

Exposure time + 1056L + 3L

Smearless is ON

Smearless time(352L) + Maximum exposure time +1056L + 3L

Note: 1) On the above table, 1056L is FVAL interval on normal continuous mode
2) In the vertical binning mode, 1L is different from the normal scanning. So, the minimum

trigger interval will be different.

Fig.41 Edge Pre-select.