Technical references error reporting, Edh and isr – Sony MK7807V1 User Manual

Page 163

Advertising
background image

161

Technical References

Error reporting

Errors are reported in five different ways:

• Error detected here, edh

• Error detected already, eda

• Unknown error status, ues

• Internal error detected here, idh

• Internal error detected already, ida

The last two reports, idh and ida, are used when a piece of equipment has the capability to

check for data corruption between its input and output.

EDH actually checks and reports each video frame in three ways, calculating separate check

sums for the complete frame, the active picture area and the ancillary area. (The ancillary area

is the area of the frame blanking interval that can contain digital audio signals and other

multiplexed information.) A reason for this division of areas is so that errors in the active picture

area can be given a higher fault priority, simply because they have direct effect on the program

audience.

Sony is supporting EDH, and an increasing number of relevant products(down to board level in

some cases) now have the ability to provide a visual eda report with an LED indicator.

EDH and ISR

In an overall system, EDH-equipped devices can report to a computer network, with status

indication displayed by a PC. EDH is complementary to the well-established Sony ISR

(Interactive Status Reporting) system, which can be used to report EDH status checks. In this

way, detailed information on the performance of individual pieces of equipment is combined

with information on the performance of their interconnections.

*SGC_0145-0161 02.3.19 5:37 PM Page 161

Advertising