3-8. Wiring Instructions for Inter-unit Connections

(1) Insert the inter-unit wiring (according to local codes)

into the through-the-wall PVC pipe. Run the wiring

toward the indoor side allowing approx. 10 inch to

extend from the wall face. (Fig. 19)

(2) Route the inter-unit wiring from the back of the

indoor unit and pull it toward the front for connection.

(Fig. 20a, 20b)

(3) Connect the inter-unit wiring to the corresponding

terminals on the terminal plate (Fig. 20a, 20b) while

referring to the wiring diagram.

(4) Be sure to secure the wiring with the provided

clamp.

How to remove the cover plate

To access the terminal plate inside the indoor unit, follow

these steps.

(1) Using a Phillips screwdriver, take out the screw on

the cover plate. (Fig. 20a, 20b)

(2) Remove the cover plate.

Rear
panel

Wiring

Wall

10 in.

Plastic
cover

Fig. 19

Terminal
plate

Cover plate

Fig. 20a

Fig. 20b

Lock nut

Top of conduit
connector

Inter-unit
control line
wiring

Earth
plate

01-386 AirCon 12/11/01 4:49 PM Page 9