2-2. Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 4a)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated.

allow enough room around the unit for air intake/

exhaust and possible maintenance. (Fig. 4b)

provide a solid base a minimum of 6 inches above

ground level to reduce humidity and protect the unit

against possible water damage and decreased service

life. (Fig. 5)

use lug bolts or equal to bolt down unit, to reduce

vibration and noise.

Outdoor unit

Hot air

Heat source

Exhaust fan

Fig. 4a

Min.
1 inch

Min.
1 inch

Min. 2 ft.

Min. 4 inches

Min.
7 ft.

Obstacle above

Ground

Air
dis-
charge

Fig. 4b

Air in

Air in

Air
discharge

Concrete block
4 inch

×

1 ft. 4 inch

beams or equal

Anchor bolts
(4 pieces)

Min. 6 inch

Fig. 5