(2) Wrap the armoring tape from the bottom of the out-

door unit to the top of the tubing where it enters the

wall. As you wrap the tubing, overlap half of each

previous tape turn. (Fig. 36)

(3) Clamp the tubing bundle to the wall, using 1 clamp

approx. every 4 ft.

Do not wind the armoring tape too tightly since this will
decrease the heat insulation effect. Also be sure the con-
densation drain hose splits away from the bundle and
drips clear of the unit and the tubing.

4-6. Finishing the Installation

After finishing insulating and taping over the tubing, use

sealing putty to seal off the hole in the wall to prevent

rain and draft from entering. Fig. 37 shows refrigerant

tubing taped separately from the drain hose.

NOTE

Apply putty here

Tubing

Fig. 37

Fig. 36

Clamp

Insulated tubes

Insulation

Min.
5/16"

Thickness:
min. 5/16"

Fig. 35