Installation site selection – Sanyo CL2432 User Manual

Page 4

Advertising
background image

3

1-6. Additional Materials Required for Installation

1.

Refrigeration (armored) tape

2.

Insulated staples or clamps for connecting wire

(See local codes)

3.

Putty

4.

Refrigeration lubricant

5.

Clamps or saddles to secure refrigerant tubing

2. Installation Site Selection

2-1. Indoor Unit

AVOID:

direct sunlight.

nearby heat sources that may affect performance of

the unit.

areas where leakage of flammable gas may be

expected.

places where large amount of oil mist exist.

DO:

select an appropriate position from which every corner

of the room can be uniformly cooled. (High on a wall

is best.)

select a location that will hold the weight of the unit.

select a location where tubing and drain hose have

the shortest run to the outside. (Fig. 1)

allow room for operation and maintenance as well as

unrestricted air flow around the unit. (Fig. 2)

install the unit within the maximum elevation differ-

ence (H) above or below the outdoor unit and within a

total tubing length (L) from the outdoor unit as detailed

in Table 3 and Fig. 3a.

Table 3

6 inches

min.

6 inches

min.

6 inches min.

Front View

Fig. 2

INDOOR
UNIT

Tubing length (L)

OUTDOOR
UNIT

Elevation
difference (H)

Fig. 3a

Max. Allowable Tubing

Limit of Tubing

Limit of Elevation

Required Amount of

Model

Length at Shipment

Length (L)

Difference (H)

Additional Refrigerant

(ft.)

(ft.)

(ft.)

(oz./ft.)

*

C2432, CL2432

25

132

50

0.27

WARNING

To prevent abnormal heat gen-
eration and the possibility of
fire, do not place obstacles,
enclosures and grilles in front
of or surrounding the air condi-
tioner in a way that may block
air flow.

*

If total tubing length becomes 25 to 132 ft. (max.), additional refrigerant (R22) charge of 0.27 oz./ft. is required.
No additional charge of compressor oil is necessary.

Indoor unit

Floor level

Wall

Minimum height
from floor level

5 ft.

Fig. 3b

For stable operation of
the air conditioner, do
not install wall-mounted
type indoor units less
than 5 ft. from floor
level.

CAUTION

Drain hose

Indoor unit

Outside drainage

Fig. 1

01-386 AirCon 12/11/01 4:48 PM Page 3