Indoor
side

Outdoor
side

Set screws for transportation only

Right-rear
tubing
(recommended)

Right tubing

Left-rear tubling

Fig. 6

Fig. 7a

Center of
left-rear
tubing hole

Center of
right-rear
tubing hole

Fig. 7b

NOTE

Hole should be made at a slight downward slant to the

outdoor side.

In case of left-rear or right-rear tubing

Fig. 8

3. How to Install the Indoor Unit

3-1. Remove the Rear Panel from the Unit

Remove and discard the set screws and take off the rear

panel. (Fig. 6)

Tubing can be extended in 3 directions as shown in

Fig. 7a. Select the direction you need providing the

shortest run to the outside unit.

3-2. Make a Hole

(1) Remove the rear panel from the indoor unit and

place it on the wall at the location selected. Make

sure the unit is horizontal, using a carpenter’s level

or tape measure to measure down from the ceiling.

(2) Determine which side of the unit you should make

the hole. (Fig. 7b)

(3) Before making a hole, check carefully that no studs

or pipes are directly run behind the spot to be cut.

The above precautions are also applicable if tubing

goes through the wall in any other location.

(4) Using a sabre saw, key hole saw or hole-cutting drill

attachment, cut a hole in the wall. See Table 4 and

Fig. 8.

Table 4

(5) Measure the thickness of the wall from the inside

edge to the outside edge and cut PVC pipe at a

slight angle 1/4" shorter than the thickness of the

wall. (Fig. 9)

(6) Place the plastic cover over the end of the pipe (for

indoor side only) and insert in the wall. (Fig. 10)

NOTE

CAUTION

Also avoid areas where electri-
cal wiring or conduits are
located.

Hole Dia. (inch)

3-3/16"

Plastic cover

(Field Supply)

OUTSIDE

INSIDE

Wall

Slight
angle

PVC pipe

Fig. 10

PVC pipe (locally purchased)

Cut at slight angle

Fig. 9