Network topologies with osm/esm – Siemens ESM User Manual

Page 36

Advertising
background image

Network Topologies with OSM/ESM

Industrial Ethernet OSM/ESM

32

C79000-Z8976-C068-10

ESM in
RM mode

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

ESM ITP 80

2 ITP XP standard cable 9/9

2

2

2

2

2

2

2

2

2

Figure 13: Redundant Ring Structure with ESMs

Notes
• The reconfiguration time of less than 0.3 s can only be achieved when no

components other than OSMs and ESMs (for example switches) are used in
the redundant ring.

• In a ring, one device and one device only must operate in the redundancy

manager mode.

• DTEs or complete network segments can be connected to ports 1 – 6

(OSM/ESM with 8 ports) or ports 1 and 2 (OSM/ESM with 4 ports) of an
OSM/ESM operating in the RM mode.