Interfaces, Displays and Operator Controls

Industrial Ethernet OSM/ESM
C79000-Z8976-C068-10

53

4.1.8 Digital

Inputs

In the case of the OSMs/ESMs with digital inputs, the states of these inputs are
available in a management information base (MIB) and can be read with an SNMP
get request. Depending on the configuration of the device, changes at these inputs
can also trigger the sending of E-mails, SNMP traps and/or entries in the log of the
OSM/ESM. The use of these functions is described in the OSM/ESM Network
Management User Manual /1/.

The digital inputs are attached using six-pin plug-in terminal blocks with screw
locking mechanisms.

I1

I2

M

M

I3

I4

I5

I6

M

M

I7

I8

Input 1

Input 2

Input 4

Input 3

Input 5

Input 6

Input 8

Input 7

Figure 25: Terminal Block for Digital Inputs

!

Warning
The input voltage must not exceed +30V DC or fall below -30V DC.