Interfaces, Displays and Operator Controls

Industrial Ethernet OSM/ESM
C79000-Z8976-C068-10

59

Full duplex

Note
LED 3 exists only on devices with digital
inputs.

Port LED

- Lit green: Port operating in full duplex

mode

- Not lit: Port operating in half duplex mode

Fault mask

Note
LED 3 exists only on devices with digital
inputs.

The fault mask indicates whether the ports
and the power supplies are monitored with
the signaling contact.
Port LED

- Lit green: Port is monitored; in other

words, if the port does not have a valid
connection (for example cable not
plugged in or attached device turned off),
the signaling contact is triggered.

- Not lit: The port is not monitored; in other

words, an invalid or valid connection at
the port does not trigger the signaling
contact.

The fault mask can be set again with the
button on the front panel of the OSM (see
4.2.4.2)

Digital inputs

Note
LED 3 exists only on devices with digital
inputs.

Port LED

- Lit green: The logical state "1" is applied

to the corresponding digital input. This
requires an input voltage of + 13 V DC to
+ 30 V DC.

- Not lit: The logical state "0" is applied to

the corresponding digital input. This
requires an input voltage of + –30 V DC
to + 3 V DC.

The basic status "Port Status" of the display is adopted automatically after turning
on the device. The device also switches automatically to this display status when
the "Select/Set" button is pressed for more than a minute.

Display

Display

LED on

LED off

LED off

LED on

LED on

LED off

Display

LED off

LED off

LED on

3

2

1

3

2

1

3

2

1