Siemens ESM User Manual

Page 65

Advertising
background image

Interfaces, Displays and Operator Controls

Industrial Ethernet OSM/ESM
C79000-Z8976-C068-10

61

4.2.4.2

"Select/Set" Button

The "Select/Set" button on the front panel of the OSM/ESM has the following
functions:

• Pressing the button briefly moves on the display of the port LEDs (display

mode). The current display mode is indicated by the display mode LEDs.

• If the display is in the port status (all display mode LEDs off) and if the button is

pressed for three seconds, the display mode LEDs begin to flash. If you then
continue to press the button for a further two seconds, the OSM/ESM is reset.

When it is reset, all the settings of the OSM/ESM are set to their defaults (as set in
the factory). This allows you to cancel settings made, for example, with Web-Based
Management (WBM) (see also OSM/ESM Network Management, User Manual).

• If the display is in the fault mask status and you press the button for two

seconds, the display LEDs start to flash. If you then press the button for a
further two seconds, the current status of the ports and the supply voltages are
entered in the fault mask. This means, if, for example, the ports 1, 5, 6 had a
valid connection (in other words the port status displays of these ports are lit
green or yellow) and if power supply 1 was active at the point when the values
were entered in the fault mask, ports 1, 5, 6 and power supply 1 will then be
monitored.

Note
If the "Select/Set" button is pressed while the device is starting up (takes
approximately 20 seconds) after turning on the OSM/ESM, the OSM/ESM changes
to the load firmware status (all display mode LEDs flash simultaneously). This
status is exited by pressing the button again. For further information on loading the
firmware, refer to Chapter 6.

Advertising
This manual is related to the following products:

OSM