Siemens ESM User Manual

Page 84

Advertising
background image

Technical Specifications

Industrial Ethernet OSM/ESM

80

C79000-Z8976-C068-10

Permitted Cable Lengths

FO cable length between two OSMs

For OSM ITP62, OSM ITP53, OSM
TP62, OSM TP22:
0-3000 m (62.5/125

µm glass fiber; 1

dB/km at 1300 nm; 600 MHz*km; 6 dB
max. permitted FO cable attenuation at 3
dB link power margin)
0-3000 m (50/125

µm glass fiber; 1

dB/km at 1300 nm; 600 MHz*km; 6 dB
max. permitted FO cable attenuation at 3
dB link power margin)
For OSM ITP62-LD:
0-26000 m (10/125

µm single mode

fiber; 0,5 dB/km at 1300 nm; 13 dB max.
permitted FO cable attenuation at 2 dB
link power margin)

ITP cable length

0-100 m

TP cable length

0-10 m with TP cord
up to 100 m total length when using the
FastConnect cabling system

Length of the ITP XP Standard Cable
9/9 at standby-sync port

0-40 m

Cascading Depth

Bus/star structure

Any (only depending on signal
propagation time)

Redundant ring

50 (for reconfiguration time < 0.3 s)

Switching Properties of OSM/ESM

Number of learnable addresses

Up to 7000

Aging time

40s (default)

Latency

4

µs (measured at 75% load between

two ports operating at 100 Mbps)

Switching procedure

Store and forward

Advertising
This manual is related to the following products:

OSM