Appendix, 1 status specifications, 1-1 enq command status – Star Micronics Dot Impact Printer User Manual
Page 91: 1-2 eot command status
 
5-1
STAR Command Specifications
Rev. 0.70
5. APPENDIX
5-1 Status Specifications
This	function	is	effective	only	when	using	an	interface	capable	of	bi-directional	data	communications.
Refer	to	your	printer’s	product	specification	manual	to	verify	if	the	interface	cable	on	the	printer	you	use	is	capable	of	
bi-directional	data	communications.
5-1-1 ENQ Command Status
This status is the one the printer transmits using the ENQ command.
Bit Contents
Status
By model
“0”
“1”
BD100
SP2000
BD500
SP500
SP700
7
Compulsion SW
Open
Closed
○
○
○
○
○
6
Buffer overflow
No error
Overflow
○
○
○
○
○
5
Reception Buffer 
Empty
Has Data
Empty
○
○
○
○
○
4
Fixed at “0”
-
-
-
-
-
-
3
Paper end
Paper
No paper
○
○
○
○
○
2
Mechanical Error
No Error
Error
○
○
○
○
○
1
Framing Error
No Error
Error
○
○
○
○
○
0
Parity Error
No Error
Error
○
○
○
○
○
• Framing error/parity error
These errors occur when using a serial I/F.(For anything other than a serial interface, always Bit 0 = Bit 1 = 0.) 
With these errors, the information at that time is held and the error status is sent when there is an inquiry of the status 
by	this	command.	
• Compulsion SW
When the conversion switch is ON, Bit 7 = 1. 
5-1-2 EOT Command Status
This status is the one the printer transmits using the EOT command.
Bit Contents
Status
By model
“0”
“1”
BD100
SP2000
BD500
SP500
SP700
7
-
-
-
-
-
6
-
-
-
-
-
5
-
-
-
-
-
4
Fixed at “1”
-
-
-
-
-
-
3
Paper end
Paper
No paper
○
○
○
○
○
2
Paper near-end
Paper
No paper
x
○
x
○
○
1
Black mark detection 
error 
No Error
Error
x
x
○
○
○
0
Fixed at “0”
-
-
-
-
-
-
• Paper end
Same as the ENQ status Bit 3
• Bit 5 to 7 states are unknown