Adjustment Using the Menus

17

USER CONFIG menu

You can select a language, etc.
Items that cannot be adjusted depending on the input
signal are displayed in blue.

Scan mode image

Submenu

Setting

RGB/COMP SEL

When a signal input via the IN
(input) connector of the RGB/
COMPONENT connector is being
monitored, based on the signal
being input, select RGB or COMP.

COMP LEVEL

Select the component level from
among three modes.
SMPTE

for 100/0/100/0 signal

BETA 0

for 100/0/75/0 signal

BETA 7.5 for 100/7.5/75/7.5

signal

NTSC SETUP

Select the NTSC setup level from
two modes.
The 7.5 setup level is used mainly
in North America. The 0 setup level
is used mainly in Japan.

GAMMA

Selects the appropriate gamma
mode. You can select from among
5 settings. When “3” is selected,
the setting is roughly same as the
gamma mode of the CRT (2.2).

FORMAT DISP

Select the display mode of the
signal format.
ON: The format is always

displayed.

OFF: The display is hidden.
AUTO: The format is displayed

for about 10 seconds when
the input of the signal
begins.

LANGUAGE

You can select the menu or message
language from among seven
languages.
ENGLISH: English
DEUTSCH: German
FRANÇAIS: French
ITALIANO: Italian
ESPAÑOL: Spanish

: Japanese

: Chinese

x R G B / C O M P S E L

xxxx

· C O M P L E V E L

xxxxx

· N T S C S E T U P

x

· G A M M A

x

· F O R M AT D I S P

xxx

· L A N G U A G E

xxx

U S E R C O N F I G ( 1 / 2 )

R r

xS C A N

xxxx

· P I C D E L A Y M I N

xxx

U S E R C O N F I G ( 2 / 2 )

R r

SCAN

Enlarge a 4:3 aspect ratio picture to
a 16:9 aspect ratio picture.
Select from “OFF” and “ZOOM”
mode.

PIC DELAY MIN

Selects to set the delay by the
picture processing to the minimum
level when the signal is input.
OFF: Mode for giving

precedence to the picture quality
(recommended mode). It takes
longer than “ON” for processing
the picture.

ON: The processing time is

short. As the line flicker is
displayed in this mode, it is
available for checking the line
flicker of the telop work and so
on.

Input

NORMAL
SCAN (5 %
OVERSCAN)

UNDER
SCAN

ZOOM

Submenu

Setting

4

3

16

9

Ou

tp

u

t

3

4

9