The WARNING indicators show the state of the function which protects the projector. Check the state of the

WARNING TEMP. indicator and the LAMP indicator to take proper maintenance.

Warning Indicators

The projector is shut down and the WARNING TEMP.

indicator is blinking red.

When the temperature inside the projector reaches a

certain level, the projector will be automatically shut down

to protect the inside of the projector. The LAMP indicator

turns red brighter and the WARNING TEMP indicator

blinks while the projector is being cooled down. When the

projector has cooled down enough (to its normal operating

temperature), it can be turned on again by pressing the ON/

STAND-BY button.

Note:

• The WARNING TEMP. indicator continues to blink even after the

temperature inside the projector returns to normal. When the projector
is turned on again, the WARNING TEMP. indicator stops blinking.

Then check the matters below:
– Did you provide appropriate space for the projector to be

ventilated? Check the installing condition to see if the air

vents of the projector are not blocked.

– Has the projector been installed near an Air-Conditioning/

Heating Duct or Vent? Move the installation of the

projector away from the duct or vent.

– Is the filter clean? Replace the filter with a new one.

CAUTION

DO NOT LEAVE THE PROJECTOR WITH THE

AC POWER CORD CONNECTED UNDER AN

ABNORMAL CONDITION. IT MAY RESULT IN FIRE

OR ELECTRIC SHOCK.

Indicators

Indicators

wARNING TEMP .
blinking red

Maintenance and Care

The projector is shut down; and the LAMP indicator is

lighting and other indicators are blinking.

When the projector detects an abnormal condition, it

will be automatically shut down to protect the inside of

the projector and the LAMP indicator lights on and other

indicators blink. In this case, unplug the AC power cord and

plug it, and then turn on the projector once again to verify

operation. If the projector cannot be turned on and these

indicators are still lighting and blinking, unplug the AC power

cord and contact the service center.

LAMP indicator lights on
and other indicators blink .