4-5

Maintenance And Specifications

Technical Specifications

Table 4-2. Technical Specifications

Item

Description

Decode Capability

The RF scanner can be programmed to decode the following
code types: UPC/EAN, Bookland EAN, Code 11, Code 39,
Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar,
Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, MSI
Plessey, and Coupon Code.
The RF scanner can auto-discriminate between all of the above
code types except for Code 39 and Code 39 Full ASCII.

Scanner Beeper Operation

User-selectable: Enabled, Disabled.

Scan Repetition Rate

35 (± 5) scans/sec (bidirectional)

Roll (Skew) Tolerance

± 30° from normal

Pitch

± 65° from normal

Yaw

± 60° from normal

Decode Depth of Field

See

Decode Zone

on page 3-24.

Print Contrast Minimum

20% absolute dark/light differential, measured at the wavelength
of the laser diode.

Ambient Light Immunity

Artificial Lighting

450 ft. candles

4844 lux

Sunlight

10,000 ft. candles

107,640 lux

Operating Temperature

P370 (Industrial)
P470 (Retail)

-4° to 122°F

-20° to 50°C

32° to 104°F

0° to 40°C

Storage Temperature

-40° to 140°F

-40° to 60°C

Sealing

P370:

All components sealed to IP 54 specification against
wind blown dust and rain.

Humidity

5% to 95% (non-condensing)

Durability (Scanner)

P370 (Industrial)
P470 (Retail)

P370:

6-ft. (1.8 m)

P470:

5-ft. (1.5 m)

Drops to concrete over entire temperature range